- Customer / Industry
OEM / Railway
- Request
Delivery of a complete lightweight underfloor battery container for on-board power supply. Classification fire protection E 30 according to EN45545.
- Special Challenge
The specified maximum weight could not be achieved with normal underfloor container construction.
- Solution
110 V NiCd battery in a high-tech lightweight underfloor container with know-how from the space sector. Duration of the implementation in 58 weeks.
- Added Value for the Customer
The specified maximum weight was still significantly undercut. This resulted in savings in the overall concept.
- Supported by
GW Batteries GmbH, Zwickau